Notice: Function Elementor\Core\Experiments\Manager::warn_removed_or_hidden_dependency was called incorrectly. Feature mega-menu depends on hidden experiment nested-elements. Please see Debugging in WordPress for more information. (This message was added in version 4.3.3.) in /home1/accura50/public_html/wp-includes/functions.php on line 6260
Warning: Cannot modify header information - headers already sent by (output started at /home1/accura50/public_html/wp-includes/functions.php:6260) in /home1/accura50/public_html/wp-includes/feed-rss2.php on line 8 Fire Safety – Accurate PMS Private Limited
https://accuratepms.in
WebsiteWed, 18 Aug 2021 20:13:19 +0000en-US
hourly
1 https://wordpress.org/?v=7.1.2https://accuratepms.in/wp-content/uploads/2021/07/favicon-square-150x150.pngFire Safety – Accurate PMS Private Limited
https://accuratepms.in
3232Fire Extinguisher
https://accuratepms.in/fire-extinguisher-safety-equipment/
Fri, 30 Jul 2021 06:30:07 +0000https://accuratepms.in/?p=806
Our Products A typical CO2 extinguisher weighs a staggering 18.5 kgs, making it extremely difficult to carry and operate. CO2 also stored at very low.
A typical CO2 extinguisher weighs a staggering 18.5 kgs, making it extremely difficult to carry and operate. CO2 also stored at very low temperatures, often causing freeze burns on the user’s hands in the process of activation.
A used / unused indicator allows the user to check, at a glance, weather the extingulisher is ready for use.
The revolutionary new squeeze grip activation, removes all risk of freeze burn, and ensures that the user can rapidly put the extinguisher to use against a fire.
An ergonomically designed handle at the center of the extinguisher distributes the load evenly to the key arm muscles, making the extinguisher easier to carry. Wheels at the base of the extinguisher also significantly improve its portability over long distances.
]]>Aspiration System
https://accuratepms.in/aspiration-system/
Fri, 30 Jul 2021 06:27:20 +0000https://accuratepms.in/?p=800
The FAAST LT Aspirating Smoke Detector is designed with the installer and end user in mind. It serves the wide varity of Class C applications where maintenance is difficult, other smoke detection methods are inappropriate or prone to fail due to harsh environments or area where aesthetics matters. It is also suitable for smaller mission critical applications where very early warning – Class A or B detection is required
FAAST LT combines proven aspiration detection technologies to deliver reliable smoke detection and efficient installation and maintenance. The device includes high sensitivity laser fre detection, ultrasonic fow sensors, and internal design features to protect vulnerable components from environmental and human threats. The device is fast to install and easy to commission thanks to PIPE UQ LT pipe design and configuration software which is included as standard.
FAAST LT stand alone device are available as single channel and dual channel devices, offering flexibility for different detection strategies. A range of customizable settings are geared towards maximizing device performance and meeting different application needs.
The detector provides alarm and fault relays with auxiliary events relay as an option. These can be set as latched or non-leached. To accommodate local installation standards or environments, fow and general fault delays can also be set.
Slnortx 1230 reacts rapidly with superior extinguishing properties – protecting valuable assets and ensuring extinguishing without negative impact on the advanced extinguishing solution sinorixTM 1230 is an excellent solution for the protection of high-value assets, business process and people. It is based on the environmentally friendly extinguishing agent 3MTM NovecTM 1230 Fire protection Fluid. The high-pressure technology from Siemens allows highest design flexibility and the realization single-sector and multi-sector systems. Enabling rapid, safe and automated inter-ventions, Sinorix 1230 can prevent loss of data and secure business continuity.
Sinorix 1230 is an effective and clean extinguishing solution that is ideally suited to extinguish smoldering fires. It causes neither damage to nor leaves any residue on sensitive equipment. This makes it the perfect choice for eliminating electrical and electronic risks.
Sinorix 1230 – typical applications
Data centers and server rooms
Telecommunication systems
Electrical switching rooms
Store rooms
Military deports
Clean rooms
Fast, highly effective and economical
The high efficiency of the Sinorix 1230 system allows using a low extinguishing concentration. Novec 1230 fluid even offers the lowest extinguishing concentration of all currently authorized extinguishing agents.
Therefore, compact system designs are possible and less space is needed for installation and cylinder storage.
Our Products With a Chemetron Fire Systems FM-200® system in control, you are assured of fast, efficient and environmentally safe fire relinquishment.
With a Chemetron Fire Systems FM-200® system in control, you are assured of fast, efficient and environmentally safe fire relinquishment.
FM-200® works to quench fires in seconds and hold damage to a minimum. No facility can afford the loss of time, money or productivity that occurs after a fire.
Chemetron FM-200® systems provide safe fire protection for occupied spaces and critical assets they also make good economic sense. FM -2000® is the agent of choice.
FM-200® is the clear choice for a fast, clean fire protection agent. Patented by Great Lakes Chemical Corporation as a Halon 1301 replacement 1993 , it has quickly gained acceptance as the world’s leading clean gaseous fire extiguishing agent.
]]>Fire Sprinkler system
https://accuratepms.in/fire-sprinkler-system/
Fri, 30 Jul 2021 06:18:26 +0000https://accuratepms.in/?p=781
In smaller workplaces, portable fire extinguishers will probably be sufficient to tackle small fires. However, in more complex buildings, or where it is necessary to protect the means of escape and/or the property or contents of the building, it may be necessary to consider a sprinkler system. Sprinkler systems are traditionally acknowledged as an efficient means of protecting buildings against extensive damage from fire. They are also now acknowledged as an effective means of reducing the risk to life from fire. Systems are being developed which may be suitable for use in workplaces with residential areas, such as care homes and houses in multiple occupancy. Sprinkler systems need to be specifically designed and installed to the appropriate hazard category in accordance with an approved code of practice.
We offer Design & Engineering of an integrated Sprinkler System with fine protection engineering standards Network of specially sized or hydraulically designed piping installed in building, structure generally overhead with attached sprinkler in a systematic pattern proper location of alarm valve and orientation as per our best design practice makes us leader in designing this system. We design sprinkler system as per TAC, NBC, Indian and NFPA Standards or guidelines.
We design Sprinkler System as per TAC, NBC, Indian and NFPA Standards or guidelines.
]]>Fire Hydrant System
https://accuratepms.in/fire-hydrant-system/
Fri, 30 Jul 2021 06:15:03 +0000https://accuratepms.in/?p=774
A fire hydrant System is an above-ground connection that provides access to a water supply for the purpose of fighting fires. Fire hydrant systems are an installation of pipes, water tanks, pumps, hydrant outlets and/or hose reels.
Hydrant Systems can be of two types :
(a) External Hydrant System, where the hydrants are installed in the open, like the city or town water mains, or hydrant systems installed in the open areas in industrial or such other occupancies; and
(b) Internal Hydrant System, installed in buildings or structures to be protected
We design an integrated Hydrant System as per national and international norms. We consider capacity of fire pump, size and arrangement of pipes used for hydrant system, pressure at hydrant point against the available fire risk. Our designed Hydrant System is an arrangement of piping, valves, hose connection and allied equipment installed in building and structure with connection located in such a manner that water can be discharge in stream of spray patterns through attached hose and nozzle for the purpose not only extinguish the fire but at the same time save the occupants and contents of area in with better response time.
We design Fire Hydrant System as per TAC, NBC, Indian,OISD and NFPA Standards or guidelines. Almost all part of the premises shall be covered by such system. Our designed system is not only complying the national and international norms or guidelines but also considered the exact requirement to minimize the cost at same time, increase the effectiveness of system for maximum gains.