Fire Safety

Our Products Fire Detection Addressable 5 analogue loops. 4×40 characters display Configuration by keypad and PC 20 Zone LED.

Fire Detection Addressable

  • 5 analogue loops.
  • 4×40 characters display
  • Configuration by keypad and PC
  • 20 Zone LED (Available up to 200 on special request)
  • 3 serial ports
  • 4 programmable output sounder circuits (monitored)
  • Fire and Fault relay(one each)
  • networking up to 99 control panels
  • Versatile networking (Cu-Cable, Optic Fiber,TCP/IP)
  • VisualeyeZ GUI compatibility
  • Loop-Battery calculator for reliable system design
  • Onlboard diagnostic
  • Meeets requirements of EN54 part 2 and 4
  • LPCB approved

Fire Detection conventional

  • Microprocessor based Fire Alarm Panel with PA amplifiers system
  • Modular design, plugin in type solid state.
  • Expandable up to 2 to 50 zone fire alarm panel.
  • Each zone with fire open short indication & sound.
  • Mains, AC fail, Rev. Battery, fuse blown,fault indication.
  • Associate with PA system, talk back system etc.
  • Battery charger & Battery Box Gacility.
  • DVD player attachable facility.
  • Gooseneck Microphone attached
  • Compatible with any make smoke & heat detector.
  •  

Fire Suppression System-FM 200

  • With a Chemetron Fire Systems FM-200® system in control, you are assured of fast, efficient and environmentally safe fire relinquishment.
  • FM-200® works to quench fires in seconds and hold damage to a minimum. No facility can afford the loss of time, money or productivity that occurs after a fire.
  • Chemetron FM-200® systems provide safe fire protection for occupied spaces and critical assets they also make good economic sense. FM -2000® is the agent of choice.
  • FM-200® is the clear choice for a fast, clean fire protection agent. Patented by Great Lakes Chemical Corporation as a Halon 1301 replacement 1993 , it has quickly gained acceptance as the world’s leading clean gaseous fire extiguishing agent.
  •  

Fire Suppression System-NOVEC-1230

  • Slnortx 1230 reacts rapidly with superior extinguishing properties – protecting valuable assets and ensuring extinguishing without negative impact on the

    dvanced extinguishing solution sinorixTM 1230 is an excellent solution for the protection of high-value assets, business process and people. It is based on the environmentally friendly extinguishing agent 3MTM NovecTM 1230 Fire protection Fluid. The high-pressure technology from Siemens allows highest design flexibility and the realization single-sector and multi-sector systems. Enabling rapid, safe and automated inter-ventions, Sinorix 1230 can prevent loss of data and secure business continuity.

    Sinorix 1230 is an effective and clean extinguishing solution that is ideally suited to extinguish smoldering fires. It causes neither damage to nor leaves any residue on sensitive equipment. This makes it the perfect choice for eliminating electrical and electronic risks.

Sinorix 1230 – typical applications

  • Data centers and server rooms
  • Telecommunication systems
  • Electrical switching rooms
  • Store rooms
  • Military deports
  • Clean rooms

 

Fast, highly effective and economical

The high efficiency of the Sinorix 1230 system allows using a low extinguishing concentration. Novec 1230 fluid even offers the lowest extinguishing concentration of all currently authorized extinguishing agents.

Therefore, compact system designs are possible and less space is needed for installation and cylinder storage.

Aspiration System

The FAAST LT Aspirating Smoke Detector is designed with the installer and end user in mind. It serves the wide varity of Class C applications where maintenance is difficult, other smoke detection methods are inappropriate or prone to fail due to harsh environments or area where aesthetics matters. It is also suitable for smaller mission critical applications where very early warning – Class A or B detection is required

FAAST LT combines proven aspiration detection technologies to deliver reliable smoke detection and efficient installation and maintenance. The device includes high sensitivity laser fre detection, ultrasonic fow sensors, and internal design features to protect vulnerable components from environmental and human threats. The device is fast to install and easy to commission thanks to PIPE UQ LT pipe design and configuration software which is included as standard.

FAAST LT stand alone device are available as single channel and dual channel devices, offering flexibility for different detection strategies. A range of customizable settings are geared towards maximizing device performance and meeting different application needs.

The detector provides alarm and fault relays with auxiliary events relay as an option. These can be set as latched or non-leached. To accommodate local installation standards or environments, fow and general fault delays can also be set.

Fire Extinguisher

  • A typical CO2 extinguisher weighs a staggering 18.5 kgs, making it extremely difficult to carry and operate. CO2 also stored at very low temperatures, often causing freeze burns on the user’s hands in the process of activation.
  • A used / unused indicator allows the user to check, at a glance, weather the extingulisher is ready for use.
  • The revolutionary new squeeze grip activation, removes all risk of freeze burn, and ensures that the user can rapidly put the extinguisher to use against a fire.
  • An ergonomically designed handle at the center of the extinguisher distributes the load evenly to the key arm muscles, making the extinguisher easier to carry. Wheels at the base of the extinguisher also significantly improve its portability over long distances.

Fire Sprinkler system

In smaller workplaces, portable fire extinguishers will probably be sufficient to tackle small fires. However, in more complex buildings, or where it is necessary to protect the means of escape and/or
the property or contents of the building, it may be necessary to consider a sprinkler system. Sprinkler systems are traditionally acknowledged as an efficient means of protecting buildings against extensive damage from fire. They are also now acknowledged as an effective means of reducing the risk to life from fire. Systems are being developed which may be suitable for use in workplaces with residential areas, such as care homes and houses in multiple occupancy. Sprinkler systems need to be specifically designed and installed to the appropriate hazard category in accordance with an approved code of practice.

We offer Design & Engineering of an integrated Sprinkler System with fine protection engineering standards Network of specially sized or hydraulically designed piping installed in building, structure generally overhead with attached sprinkler in a systematic pattern proper location of alarm valve and orientation as per our best design practice makes us leader in designing this system. We design sprinkler system as per TAC, NBC, Indian and NFPA Standards or guidelines.

We design Sprinkler System as per TAC, NBC, Indian and NFPA Standards or guidelines.